Nuvia S is an ultra-high capacity, next-generation cation exchange resin built on the industry-proven UNOsphere™ base matrix technology. Nuvia S resin may be used in both the capture and polishing of biotherapeutics.

描述

Request Samples

Nuvia S Resin is an ultra-high capacity, next-generation cation exchange resin built on the industry proven UNOsphere™ base matrix technology. Nuvia S Resin provides very high capture and exceptional flow properties designed to meet current and future process needs. Nuvia S Resin is a flexible alternative that may be used both as a capture or polishing solution. The media delivers superior binding capacity over a wide operational window, making it the tool of choice for a wide range of downstream processes.

Nuvia S Resin delivers value and flexibility by allowing users to:

  • Use less media to purify a given amount of product
  • Reduce cycle time and increase productivity by operating at higher flow rates
  • Reduce costs and space requirements by decreasing buffer consumption
  • Reduce capital and operating expenses through the use of smaller columns
  • Chemical stability to withstand repetitive clean-in-place cycles
  • Flexibility in use for capture or polish steps
  • Fully supported for regulatory submission

More Information

Nuvia S Cation Exchange Resin Product Information Sheet Bulletin 5987

Instruction Manual, Nuvia S and Q High-Capacity Ion Exchange Resins 10018215

Related Technologies

  • Ion Exchange Chromatography

  • Introduction to Chromatography

Related Products

  • Nuvia Q Resin

技术指标

Type of ion exchanger
Strong cation

官能团
–SO3

Total ionic capacity
90–150 µeq/ml

Dynamic binding capacity*: 300 cm/hr
≥110 mg/ml

Shipping counterion
Na+

Median particle size
85 ± 15 µm

Operational flow rate**
50–600 cm/hr

Chemical stability: 1.0 N NaOH (20ºC)
Up to 1 week

Chemical stability: 0.1 N NaOH (20ºC)***
Up to 5 years

Gel bed compression ratio
1.15–1.18 (settled bed volume/packed bed volume)

pH stability short-term***
2–14

pH stability long-term***
4–13

Shipping solution
20% ethanol + 0.1 M NaCl

再生
1–2 M NaCl

清结剂
0.5–1.0 N NaOH

储存条件
20% ethanol or 0.1 N NaOH

 
 

* 10% breakthrough capacity determined with 4.5 mg/ml human
IgG in 40 mM NaOAc + 30 mM NaCl, pH 5.0.
 

** Recommended elution flow rates are ≤ 150 cm/hr to minimize viscosity-induced backpressure.
 

*** Data derived under accelerated conditions at 60°C.
 

订购

items

Use the filters below to refine results!

Nuvia S Resin | Bio-Rad Laboratories

(停产) Nuvia™ S Media

1560311

25 ml, strong cation exchange chromatography media, 85 μm particle size

Nuvia S Resin | Bio-Rad Laboratories

(停产) Nuvia™ S Media

1560313

100 ml, strong cation exchange chromatography media, 85 μm particle size

Nuvia S Resin | Bio-Rad Laboratories

(停产) Nuvia™ S Media

156-0315

500 ml, strong cation exchange chromatography media, 85 μm particle size

Nuvia S Resin | Bio-Rad Laboratories

(停产) Nuvia™ S Media

156-0317

10 L , strong cation exchange chromatography media, 85 μm particle size

Nuvia S Resin | Bio-Rad Laboratories

(停产) Foresight™ Nuvia™ S Plates

7324701

2 x 96-well plates, 20 μl, filter plate prepacked with Nuvia S Strong Cation Exchange Chromatography Media

Nuvia S Resin | Bio-Rad Laboratories

(停产) Foresight™ Nuvia™ S RoboColumn Unit

7324801

1 row of 8 columns, 200 μl, RoboColumn unit prepacked with Nuvia S Strong Cation Exchange Chromatography Media

Nuvia S Resin | Bio-Rad Laboratories

(停产) Foresight™ Nuvia™ S RoboColumn Unit

7324802

1 row of 8 columns, 600 μl, RoboColumn unit prepacked with Nuvia S Strong Cation Exchange Chromatography Media

Nuvia S Resin | Bio-Rad Laboratories

(停产) Foresight™ Nuvia™ S Column

7324720

Pkg of 1, 1 ml, column prepacked with Nuvia S Strong Cation Exchange Chromatography Media

Nuvia S Resin | Bio-Rad Laboratories

(停产) Foresight™ Nuvia™ S Column

7324740

Pkg of 1, 5 ml, column prepacked with Nuvia S Strong Cation Exchange Chromatography Media

相关资料

Login Required

Number 描述 Options

3218

A Blueprint for Robust, Cost- Efficient Biosimilar Purification Using Ion Exchange Resins

Log In to download this document

6895

Resin Functionalities Maximize Process Value For Biomolecule Purifications

Log In to download this document

[ Add to Cart (Free) ]

7130

Improved Process Economics of HUMIRA Biosimilar Purification with Ion Exchange and Mixed-Mode Resins Application Note

Log In to download this document

7134

A Non-Affinity Chromatography Resin Alternative for Capture Purification of Antibodies Application Note

Log In to download this document

5987

Nuvia S Cation Exchange Media Product Information Sheet

Log In to download this document

10018215

Instruction Manual, Nuvia S and Q High-Capacity Ion Exchange Media

Log In to download this document

7382

Purification of a Recombinant Monoclonal Antibody — a Rituximab Biosimilar — with a Non–Affinity Based Chromatographic Process

Log In to download this document

6242

Nuvia™ cPrime™ Hydrophobic Cation Exchange Resin Product Information Sheet, Rev C

Log In to download this document

6983

Native and Recombinant Protein Purification Resins/Media Selection Card

Log In to download this document

6786

Monoclonal Antibody Purification Resin Selection Card, Ver A

Log In to download this document

6789

IgG Polyclonal Antibody Purification Resin Selection Card, Ver A

Log In to download this document

6792

Aggregate Purification Resin Selection Card, Ver A

Log In to download this document

6966

Development of a Non–Affinity Based Purification Platform for Neutral/Basic IgMs

Log In to download this document

6955

Non–Affinity Based Purification Platform for Neutral/Basic IgMs (Poster)

Log In to download this document

6711

Purification of Amyloidogenic Transthyretin Protein Using Nuvia™ Q Anion Exchange Resin, Rev A

Log In to download this document

6720

Development of a cGMP-Ready Purification Process for Adenovirus Purification (Poster), Rev A

Log In to download this document

RP0049

The Effect of Conductivity on Dynamic Binding Capacity on CEX Resins Tech Poster, Rev A.

Log In to download this document

6719

Development of an Efficient Manufacturing Process for Adenovirus, Ver A

Log In to download this document

6875

Practical Guide: Selecting the Optimal Resins for Monoclonal Antibody Process Purification, Ver A

Log In to download this document

6810

Practical Guide: Selecting the Optimal Resins for the Process Purification of Native and Recombinant Proteins, Ver A

Log In to download this document

6808

Practical Guide: Selecting the Optimal Resins for Aggregate Removal, Ver A

Log In to download this document

6790

Practical Guide: Selecting the Optimal Resins for Mammalian Virus Process Purification and Clearance, Ver A

Log In to download this document

6881

Practical Guide: Selecting the Optimal Resins for Removal of DNA Contamination during Process Purification, Ver A

Log In to download this document

6889

Novel Selectivities and Workflows to Streamline mAb Purification Processes, Ver A

Log In to download this document

6869

Nuvia™ Chromatography Resins Publications List, Ver A

Log In to download this document

6861

Monoclonal Antibody Purification: Capture Purification Resins Brochure, Ver A

Log In to download this document

6887

Quick Monoclonal Antibody Purification Strategy: Non-Affinity Based Capture Flier, Ver A

Log In to download this document