伯乐CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

The CFX96 Optical Reaction Module converts a C1000 Touch Thermal Cycler into a real-time PCR system. This six-channel system combines advanced optical technology with precise thermal control.

描述

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

Product Discontinuation

The CFX Touch 96-well and 394-well Real-Time PCR Detection Systems will be discontinued soon. Please see the CFX Opus Real-Time PCR System for alternative products. We will continue to provide support for the CFX Touch 96-well and 384-well Real-Time PCR Detection Systems until December 2026.

Request a Demo

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

CFX Loyalty Program
Earn a free one-year service contract on your CFX System.

Learn More »

 

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

Real-Time PCR Tips, Tricks, and Best Practices Guide

Get the Guide »

The CFX96 Touch System is a powerful, precise, and flexible real-time PCR detection system. This six-channel (five colors and one FRET channel) real-time PCR instrument combines advanced optical technology with precise temperature control to deliver sensitive, reliable detection for singlexplex or multiplex reactions.

Quickly set up runs and monitor amplification traces in real time on the integrated LCD touch screen, or use the included CFX Maestro Software to easily and intuitively design your experiment and analyze results from a connected computer. With up to five-target detection, unsurpassed thermal cycler performance, unrivaled stand-alone functionality, and powerful yet easy-to-use software, the CFX96 Touch System is designed to advance your qPCR.

Key Features and Benefits

With the CFX96 Touch Real-Time PCR Detection System you can:

  • Set up your system quickly — easy installation and factory-calibrated optics
  • Minimize sample and reagent use — up to 5-target multiplexing with sample volumes as low as 10 µl
  • Optimize reactions in a single run — thermal gradient feature
  • Analyze data faster — visualize all run data at once and export only the data you need in the format you want
  • Use advanced data analysis tools — normalized gene expression using CFX Maestro Software
  • Configure the system to fit your needs — run without a computer, run up to 4 systems from 1 computer, or integrate with the CFX Automation System II for higher throughput
  • Combine the CFX96 Touch System with good laboratory practice standards — use CFX Maestro Software, Security Edition for data collection and analysis to simplify compliance with U.S. FDA 21 CFR Part 11 regulations

Flexible CFX System Configurations Meet Your Throughput Needs

The CFX Automation System II works with all CFX Real-Time PCR Detection Systems to enable walk-away, high-throughput qPCR operation. Integrate this robotic plate handler with one or two CFX Systems to maximize throughput while maintaining a compact footprint.

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

CFX Maestro Software Works Seamlessly with PrimePCR Assays and Panels

The expert design and wet-lab validation of all PrimePCR Assays ensure optimal assay performance. The integration of CFX Maestro Software with PrimePCR Assays aids in the analysis and interpretation of experimental results.

  • Begin analyzing data in a single step by importing target, reference, and control information from a PrimePCR run file directly into CFX Maestro Software
  • Combine data from multiple plates into a Gene Study to rapidly screen large numbers of targets or samples
  • Use powerful data visualization tools, such as hierarchical clustering and color-matched expression levels, to identify individual targets or clusters to consider for further investigation

Service Plans and Validation Tools for CFX Systems, Thermal Cyclers, and Real-Time PCR Instruments

  • The Bio-Rad Expert Care Service Program offers various service plans to keep your systems functioning optimally
  • CFX System IQ/OQ Services and CFX Automation System II IQ/OQ Services certify system installation and validate system performance
  • Thermal Validation Services test temperature accuracy and uniformity
  • The CFX Qualification Plate quickly and easily verifies the performance of your CFX Real-Time PCR Detection Systems

Related Technologies

  • Analysis of Stem Cells

  • Genomics

  • What is Gene Expression Analysis?

  • Real-Time PCR Experimental Design

  • What is Real-Time PCR (qPCR)?

  • Introduction to qPCR Instrumentation

  • Mutational Analysis

  • MIQE and RDML Guidelines

Related Products

  • C1000 Touch PCR 仪

  • S1000 PCR 仪

  • CFX384 Touch™ 荧光定量 PCR 检测系统

技术指标

PCR 仪
 

Chassis
C1000 Touch™

Maximum ramp rate, °C/sec
5

Average ramp rate, °C/sec
3.3

加热和冷却方法
Peltier

Lid, °C
Heats up to 105

温度
 

Range, °C
0–100

Accuracy, °C
±0.2 of programmed target at 90°C

Uniformity, °C
±0.4 well-to-well within 10 sec of arrival at 90°C

梯度
 

Operational range, °C
30–100

Programmable span, °C
1–24

光学检测
 

激励
6 filtered LEDs

检测
6 filtered photodiodes

激发/发射波长的范围,nm
450–730

Sensitivity
Detects 1 copy of target sequence in human genomic DNA

动态范围
10 orders of magnitude

扫描时间
 

所有通道,秒
12

FAM/SYBR® Green only, sec
3

软件
 

操作系统
Windows 7, Windows 8, Windows 10

多重分析
Up to 5 targets per well

系统
 

已针对荧光定量 PCR 进行许可
Yes

样本载量,孔
96

Sample size, µl
1–50 (10–25 recommended)

通信接口
USB 2.0

电气认证
IEC, CE

尺寸(宽 x 深 x 高),cm/in
33 x 46 x 36 /13 x 18 x 14

Weight, kg/lb
21/47

订购

items

Use the filters below to refine results!

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) CFX96 Optical Reaction Module for Real-Time PCR Systems with Starter Package

1845096

96–well optical module for real-time PCR, includes CFX Maestro Software, qbase+ Software license, cables, reagents, consumables, for use with C1000 Touch™ Thermal Cycler Chassis

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) CFX96 Optical Reaction Module for Real-Time PCR Systems

1845097

96-well optical module for real-time PCR, includes cables, for use with C1000 Touch Thermal Cycler Chassis

配套设备

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) CFX Qualification Plate

1845098

Predispensed 96-well plate for performance validation of CFX96™, CFX96 Touch™, CFX96 Touch™ Deep Well, or CFX Connect™ Real-Time PCR Detection System, includes template DNA, primers, supermix, water

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) PX1 PCR Plate Sealer

1814000

PCR plate sealer, includes heat sealing instrument, plate support block that holds 96-well and 384-well plates, sealing frame, power cord

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) 1000-Series Connectivity Kit

1841001

Kit contains mouse, mouse pad, USB flash drive

试剂&试剂盒

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) SsoAdvanced™ Universal SYBR® Green Supermix, 500 x 20 µl rxns, 5 ml (5 x 1 ml)

1725271

5 ml (5 x 1 ml vials), 2x qPCR mix, contains dNTPs, Sso7d fusion polymerase, MgCl2, SYBR® Green I, ROX Normalization Dyes, for 500 x 20 µl reactions

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) SsoAdvanced Universal Probes Supermix, 500 x 20 µl rxns, 5 ml (5 x 1 ml)

1725281

5 ml (5 x 1 ml vials), 2x qPCR mix, contains dNTPs, Sso7d fusion polymerase, MgCl2, stabilizers, ROX Normalization Dyes, for 500 x 20 µl reactions

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) iTaq™ Universal SYBR® Green Supermix, 500 x 20 µl rxns, 5 ml (5 x 1 ml)

1725121

500 x 20 µl reactions, 5 ml (5 x 1 ml), 2x qPCR mix, contains dNTPs, iTaq DNA Polymerase, MgCl2, SYBR® Green I, enhancers, stabilizers, and a blend of passive reference dyes

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) iTaq™ Universal Probes Supermix, 500 x 20 µl rxns, 5 ml (5 x 1 ml)

1725131

500 x 20 µl reactions, 5 ml (5 x 1 ml), 2x qPCR mix, contains dNTPs, iTaq DNA Polymerase, MgCl2, enhancers, stabilizers, and ROX Normalization Dyes

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) SsoAdvanced™ PreAmp Supermix, 50 x 50 µl rxns, 1.25 ml

1725160

1.25 ml (1 x 1.25 ml), 2x PreAmp Mix contains dNTPs, Sso7d fusion polymerase, salts, enhancers, stabilizers, and other proprietary components, for 50 x 50 µl reactions

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) SingleShot™ SYBR® Green Kit for Cell Lysis and RT-qPCR, 100 x 50 µl reactions

1725085

Pkg of 1, kit includes SingleShot Cell Lysis Reagents, iScript™ Advanced cDNA Synthesis Kit for RT-qPCR, SsoAdvanced™ Universal SYBR® Green Supermix, and the SingleShot RNA Control, for 100 x 50 µl reactions

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) iScript™ Advanced cDNA Synthesis Kit, 100 x 20 µl rxns

1725038

100 x 20 µl reactions, includes 400 µl 5x iScript Advanced Reaction Mix, 100 µl iScript Advanced Reverse Transcriptase

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) iScript™ Reverse Transcription Supermix, 100 x 20 µl rxns, 400 µl

1708841

100 x 20 µl reactions, 4 x 100 µl 5x supermix, contains reverse transcriptase, RNase inhibitor, dNTPs, primers, MgCl2, stabilizers; 50 reactions of no-RT control supermix

Plastics

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) Hard-Shell® 96-Well PCR Plates, low profile, thin wall, skirted, white/clear

HSP9601

Pkg of 50, white shell/clear well PCR plate, rigid 2-component design

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) Hard-Shell® 96-Well PCR Plates, low profile, thin wall, skirted, white/clear, barcoded

HSP9901

Pkg of 50, white shell/clear well PCR plate, barcoded, 7-digit sequential, Code 128, rigid 2-component design

The following replacement is recommended:

  • Hard-Shell® 96-Well PCR Plates, low profile, thin wall, skirted, white/white ( HSP9655 )
本产品不再供货。欲了解更多关于更换产品的信息,请联系移动电话

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) Hard-Shell® 96-Well PCR Plates, low profile, thin wall, skirted, white/white

HSP9655

Pkg of 50, white shell/white well PCR plate for higher fluorescent signals, rigid 2-component design

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) Multiplate™ 96-Well PCR Plates, low profile, unskirted, clear

MLL9601

Pkg of 25, clear PCR plate, one-component polypropylene, can be cut for fewer samples

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) Multiplate™ 96-Well PCR Plates, low profile, unskirted, white

MLL9651

Pkg of 25, white PCR plate, one-component polypropylene, can be cut for fewer samples

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) Microseal 'B' PCR Plate Sealing Film, adhesive, optical

MSB1001

Pkg of 100, optically clear seal for PCR plates

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) 0.2 ml 8-Tube PCR Strips without Caps, low profile, clear

TLS0801

Pkg of 120, thin-wall polypropylene 8-tube strips for PCR and low-volume reactions, clear (960 tubes)

CFX96 Touch Real-Time PCR Detection System | Bio-Rad Laboratories

(停产) 0.2 ml 8-Tube PCR Strips without Caps, low profile, white

TLS0851

Pkg of 120, thin-wall polypropylene 8-tube strips for PCR and low-volume reactions, white (960 tubes)

(停产) 0.2 ml Flat PCR Tube 8-Cap Strips, optical, ultraclear

TCS0803

Pkg of 120, 8-cap strips for 0.2 ml tubes and plates for PCR and optical reactions, ultraclear

下载

CFX96™ and CFX384™ Real-Time PCR Detection Systems Firmware Update
SOFT-CFX-FW
Ensures optimal performance from your instrument. Version HC12 1.0.176, PXA270 3.3.155.524, DSP 1.124, and 8051 Smartlid 0.54

Download Software

Software Download

Sorry, an error has occurred. Please try again. If the problem persists, please call {0} for assistance.

EXPORT COMPLIANCE REQUIREMENTS

Export of any Bio-Rad product or technical information relating to the product (i.e., manuals, memoranda, specifications, schematics, etc.) outside of the United States is subject to U.S. export control laws, including but not limited to the U.S. Export-Re-export Requirements and Enhanced Proliferation Control Initiative.

You agree that, unless You receive prior authorization from the United States government, You and/or Your organization shall not:

  1. use any Bio-Rad product if You are located in, under the control of, or a national or resident of any embargoed or restricted* countries (Cuba, Iran, *North Korea, Sudan, and *Syria); or
  2. sell, license, or otherwise provide or ship, directly or indirectly, any Bio-Rad product or technical data (or the direct product thereof) for export or re-export to the embargoed or restricted* countries (Cuba, Iran, *North Korea, Sudan, and *Syria); or
  3. transfer, export or re-export any Bio-Rad product to Your customers or any intermediate entity in the chain of supply if any Bio-Rad product will be used in the design, development, production, stockpiling or use of missiles, chemical or biological weapons or for nuclear end uses; or
  4. transfer, export or re-export, directly or indirectly, any Bio-Rad product, technology or software (or any part thereof, or the product of such technology or software, or any process or service which is the product of such technology or software) to any person or entity identified by the U.S. Department of Commerce as a sanctioned and/or embargoed person or entity. (For a current list of all sanctioned and/or embargoed persons or entities, please consult the U.S. Department of Commerce).

All rights to use the Bio-Rad product(s) are granted on condition that such rights are forfeited if You fail to comply with the terms of these Export Compliance Requirements.

For more information regarding U.S. export laws and regulations, contact the U.S. Department of Commerce and the U.S. Department of the Treasury, Office of Foreign Assets Control.

I agree with the compliance requirements.
(You are required to agree in order to download the software.)

Please agree to the compliance requirements for downloading the software.

下载


Log In to download software

Precision Melt Analysis™ v1.2 Software Upgrade
SOFT-PM-12-PATCH
Upgrade Precision Melt Analysis Software from version 1.0 or 1.1 to version 1.2 for use with CFX Manager™ Software version 2.0 and higher

Download Software

Software Download

Sorry, an error has occurred. Please try again. If the problem persists, please call {0} for assistance.

EXPORT COMPLIANCE REQUIREMENTS

Export of any Bio-Rad product or technical information relating to the product (i.e., manuals, memoranda, specifications, schematics, etc.) outside of the United States is subject to U.S. export control laws, including but not limited to the U.S. Export-Re-export Requirements and Enhanced Proliferation Control Initiative.

You agree that, unless You receive prior authorization from the United States government, You and/or Your organization shall not:

  1. use any Bio-Rad product if You are located in, under the control of, or a national or resident of any embargoed or restricted* countries (Cuba, Iran, *North Korea, Sudan, and *Syria); or
  2. sell, license, or otherwise provide or ship, directly or indirectly, any Bio-Rad product or technical data (or the direct product thereof) for export or re-export to the embargoed or restricted* countries (Cuba, Iran, *North Korea, Sudan, and *Syria); or
  3. transfer, export or re-export any Bio-Rad product to Your customers or any intermediate entity in the chain of supply if any Bio-Rad product will be used in the design, development, production, stockpiling or use of missiles, chemical or biological weapons or for nuclear end uses; or
  4. transfer, export or re-export, directly or indirectly, any Bio-Rad product, technology or software (or any part thereof, or the product of such technology or software, or any process or service which is the product of such technology or software) to any person or entity identified by the U.S. Department of Commerce as a sanctioned and/or embargoed person or entity. (For a current list of all sanctioned and/or embargoed persons or entities, please consult the U.S. Department of Commerce).

All rights to use the Bio-Rad product(s) are granted on condition that such rights are forfeited if You fail to comply with the terms of these Export Compliance Requirements.

For more information regarding U.S. export laws and regulations, contact the U.S. Department of Commerce and the U.S. Department of the Treasury, Office of Foreign Assets Control.

I agree with the compliance requirements.
(You are required to agree in order to download the software.)

Please agree to the compliance requirements for downloading the software.

下载


Log In to download software

64-Bit OS PC Patch
SOFT-64-PATCH
Patch installs Windows 64-bit operating system PC drivers compatible with CFX96™ and CFX384™ real-time PCR detection systems controlled by CFX Manager™ software

Download Software

Software Download

Sorry, an error has occurred. Please try again. If the problem persists, please call {0} for assistance.

EXPORT COMPLIANCE REQUIREMENTS

Export of any Bio-Rad product or technical information relating to the product (i.e., manuals, memoranda, specifications, schematics, etc.) outside of the United States is subject to U.S. export control laws, including but not limited to the U.S. Export-Re-export Requirements and Enhanced Proliferation Control Initiative.

You agree that, unless You receive prior authorization from the United States government, You and/or Your organization shall not:

  1. use any Bio-Rad product if You are located in, under the control of, or a national or resident of any embargoed or restricted* countries (Cuba, Iran, *North Korea, Sudan, and *Syria); or
  2. sell, license, or otherwise provide or ship, directly or indirectly, any Bio-Rad product or technical data (or the direct product thereof) for export or re-export to the embargoed or restricted* countries (Cuba, Iran, *North Korea, Sudan, and *Syria); or
  3. transfer, export or re-export any Bio-Rad product to Your customers or any intermediate entity in the chain of supply if any Bio-Rad product will be used in the design, development, production, stockpiling or use of missiles, chemical or biological weapons or for nuclear end uses; or
  4. transfer, export or re-export, directly or indirectly, any Bio-Rad product, technology or software (or any part thereof, or the product of such technology or software, or any process or service which is the product of such technology or software) to any person or entity identified by the U.S. Department of Commerce as a sanctioned and/or embargoed person or entity. (For a current list of all sanctioned and/or embargoed persons or entities, please consult the U.S. Department of Commerce).

All rights to use the Bio-Rad product(s) are granted on condition that such rights are forfeited if You fail to comply with the terms of these Export Compliance Requirements.

For more information regarding U.S. export laws and regulations, contact the U.S. Department of Commerce and the U.S. Department of the Treasury, Office of Foreign Assets Control.

I agree with the compliance requirements.
(You are required to agree in order to download the software.)

Please agree to the compliance requirements for downloading the software.

下载


Log In to download software

相关资料

Login Required

Number 描述 Options

7444

A Model qPCR System Comparability Study: CFX Touch and CFX Opus Real-Time PCR Platforms

Log In to download this document

7180

CFX96 Touch Protein Thermal Shift Assay Protocol

Log In to download this document

6093

CFX96 Touch™ Real-Time PCR Detection System Brochure

Log In to download this document

[ Add to Cart (Free) ]

6894

Tips, Tricks & Best Practices: The Ultimate qPCR Assay Design Guide

Log In to download this document

[ Add to Cart (Free) ]

10000068706

C1000 Touch™ Thermal Cycler and CFX Real-Time PCR Detection Systems Instrument Guide, Ver A

Log In to download this document

6900

CFX Maestro Software Brochure

Log In to download this document

[ Add to Cart (Free) ]

10000068703

CFX Maestro Software User Guide

Log In to download this document

10000115381

CFX96 Touch and CFX96 Touch Deep Well Real-Time PCR Detection Systems Installation Quick Guide, Ver D

Log In to download this document

10027341

CFX Qualification Plate — 96-Well Plate Format Product Insert

Log In to download this document

10000115384

Checking Firmware and Software Updates for the C1000 Touch Thermal Cycler and the CFX96 Touch, CFX96 Touch Deep Well, and CFX384 Touch Real-Time PCR Detection Systems, Quick Guide, Ver D

Log In to download this document

6144

Plate Preparation for the CFX384™ Real-Time PCR Detection System Using a Tecan Robotics System, Rev A

Log In to download this document

6149

Plate Preparation for the CFX384™ Real-Time PCR Detection System Using the IDEX Health & Science Innovadyne Dispenser, Rev A

Log In to download this document

5690

CFX Manager™ Software, Security Edition Product Information Sheet, Rev A

Log In to download this document

10022527

Amplification Plastics and Reagents Selection Guide

Log In to download this document

5990

Gene Expression Analysis Solutions Brochure

Log In to download this document

[ Add to Cart (Free) ]

6629

High-Throughput Real-Time PCR Solutions Brochure

Log In to download this document

5279

Real-Time PCR Applications Guide, Rev B

Log In to download this document

7216

End the Cycle of Repeated, Failed Experiments with a Robust Field Guide to qPCR

Log In to download this document

6047

Optical Design of CFX96™ Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye, Rev A

Log In to download this document

5692

Real-Time qPCR as a Tool for Evaluating RNAi-Mediated Gene Silencing, Rev A

Log In to download this document

5962

Fast Optimization of a Multiplex Influenza Identification Panel Using a Thermal Gradient, Rev A

Log In to download this document

6634

A Fast Semi-Automated Quantitative PCR Method for Monitoring Differential Gene Expression for Drug Target Discovery, Ver B

Log In to download this document

6763

Gene Expression Real-Time PCR Workflow Flier

Log In to download this document

[ Add to Cart (Free) ]

6777

Protocol for Single Cell Gene Expression Profiling by Multiplex RT-qPCR

Log In to download this document